Central construction rules - tunnelling ventilation and confined-space entry
Central · Requirement · Version 1
Applicability
Rules 31(iii), (v), (viii)-(ix) and 32 address atmospheric risks in building or other construction work. Tunnelling-specific instruments and ventilation duties apply to the tunnelling site. This extract covers atmospheric entry and ventilation controls; it supplies no work-at-height or excavation-support thresholds. Scoped operative extract of final GSR 345(E), published 8 May 2026. Central-rule and appropriate-government jurisdiction must match the establishment and work; this record does not assert a blanket replacement of State/UT rules. The canonical original PDF is unchanged and is not represented as a newly consolidated whole-rulebook review.
Dangerous-atmosphere entry safeguards
When employees must enter an area with possible toxic or harmful substances, oxygen deficiency or a flammable atmosphere, take adequate measures to guard against danger.
Construction workplace ventilation
Constantly provide adequate ventilation at all construction workplaces to remove smoke, fumes, steam and dust, dilute inflammable or noxious gases to render them harmless, supply sufficient oxygen, and prevent harmful rises in temperature or humidity.
Air measurement records
Regularly measure air quantity, temperature and humidity, and bring the entries at each air measurement station up to date.
Tunnelling ventilation requirements
Required tunnelling instruments
Compressor air-intake location
Locate air-supply intake points for all air compressors where intake air is not contaminated by dust, fumes, vapour, exhaust gases or other contaminants.
Emission and exposure controls
Minimise workplace gas, fume, vapour and dust emissions. Limit employee exposure to respirable dust, gas, fume or vapour as far as reasonably practicable, without exceeding limits harmful to employee health.
Confined-space entry condition
Do not require or allow an employee to enter a workplace or confined space until all practicable measures have brought any noxious gas, fume, vapour or dust present within permissible limits.