OSH Central Rules — shelters, rest rooms and lunchrooms

Central · Requirement · Version 3

Checked extractOfficial source available

Applicability

Applies only where the Central Government is the appropriate Government under section 2(1)(d)(i) of the OSH Code. The lunchroom trigger is ordinary employment of more than 50 workers in a factory or mine, or a required overnight halt by an employee of a motor transport undertaking.

Lunchroom triggers and facilities

The employer must provide a sufficient and suitable lunchroom where employees can eat their meals, with drinking water and washing facilities. The duty applies in a factory or mine ordinarily employing more than 50 workers and in a motor transport undertaking where an employee is required to halt at night.

Source reference: Occupational Safety, Health and Working Conditions (Central) Rules, 2026 · PDF p. 180. Rule 56(i), thresholds and lunchroom

Separate facilities and canteen compliance

The employer must provide and maintain these facilities separately for male, female and transgender employees. Rule 56 treats a canteen maintained in accordance with Rule 53 as compliance with Rule 56.

Source reference: Occupational Safety, Health and Working Conditions (Central) Rules, 2026 · PDF p. 180. Rule 56(ii) and its canteen proviso

Shelter, rest room and lunchroom standards

Keep shelters, rest rooms and lunchrooms adequately lit, ventilated, clean and hygienic at all times. Use suitable heat-resistant materials for the walls and roof, provide a suitable roof height and enough floor area for employees present at any given time, and furnish each room with suitable seating and eating arrangements.

Source reference: Occupational Safety, Health and Working Conditions (Central) Rules, 2026 · PDF p. 181. Rule 56(iii)(a)–(d), room conditions and furnishings

Source document

Official sources & provenance

Occupational Safety, Health and Working Conditions (Central) Rules, 2026

Ministry of Labour and Employment, Government of India

Published
8 May 2026
Effective from
8 May 2026
Verification
reviewed
Captured
01/10/2026
PDF SHA-256
e70b1398caedc1f28f0e135bbed9fd942d5435669eeffdef04ef2050b3665fae
View official source ↗View captured PDF ↗

Central rules under the corresponding Code. Appropriate-government jurisdiction and each rule determine applicability; this is not a blanket substitute for state rules.

Captured statutory text, not a consolidated compliance opinion. Check the applicable section, appropriate government, commencement notification, amendments and state rules before applying it to an establishment. Activity field research remains incomplete.

Back to library records