Mine rescue stations: breathing-apparatus tests and oxygen purity
Central · Requirement · Version 1
Checked extractOfficial source available
Applicability
Final G.S.R.573(E) standard under Central OSH Rules 2026 rule 131(5), issued 1 July and published 6 July 2026. Applies to breathing and resuscitating apparatus and flow meters at mine rescue stations and rooms, and oxygen supplied for breathing apparatus. The one-percent impurity limit concerns supplied oxygen, not air in a work area or a general confined-space entry threshold. Actual apparatus readings, signatures and manufacturer-specific limits are establishment records.
Apparatus testing interval
Thoroughly test every breathing and resuscitating apparatus at least once every month, or at a shorter interval recommended by its manufacturer, using paragraph 2 procedures.
Examine with particular attention to every delicate and perishable part.
2(ii)
Leakage
Test and record observations; leakage above the manufacturer's permissible limit makes the apparatus unsafe for use.
2(iii)
Cylinder oxygen pressure
Measure and record.
2(iv)
Automatic relief valve, where present
Measure discharge pressure; it must be within IS 10245 (Part-1), or its latest BIS version, limits.
2(v)
Oxygen delivery rate
Measure with the manufacturer-specified tester, within IS 10245 (Part-1) or latest BIS version limits; record measurements and adjustments in a bound paged book or non-editable electronic form.
2(vi)
Automatic demand valve, where fitted
Measure operating pressure within IS 10245 (Part-1) or latest BIS version limits; record measurements and adjustments in a bound paged book or non-editable electronic form.
2(vii)
Other manufacturer-recommended tests/adjustments, if any
Perform and record in a bound paged book or non-editable electronic form.
Record required particulars forthwith in a bound paged book or non-editable electronic form at the rescue room/station. The tester must sign or e-sign and date; the Superintendent must countersign or e-sign.
Final standard under Central OSH Rules 2026 rule 131(5). Breathing and resuscitating apparatus and flow meters at mine rescue stations and rooms, and oxygen supplied for breathing apparatus. Oxygen impurity limit is a supply specification, not a confined-space atmospheric limit.
Official native text and rendered pages independently read. Only the stated provisions are reviewed; not a consolidated whole-instrument review.
Occupational Safety, Health and Working Conditions (Central) Rules, 2026
Ministry of Labour and Employment, Government of India
Central rules under the corresponding Code. Appropriate-government jurisdiction and each rule determine applicability; this is not a blanket substitute for state rules.
Captured statutory text, not a consolidated compliance opinion. Check the applicable section, appropriate government, commencement notification, amendments and state rules before applying it to an establishment. Activity field research remains incomplete.