Belowground mine entrance: prescribed rescue equipment

Central · Requirement · Version 1

Checked extractOfficial source available

Applicability

Final G.S.R.572(E), under Central OSH Rules 2026 rule 131(2). Applies to the surface or entrance of a belowground mine where no rescue room is located close to the entrance. Equipment must be provided and maintained for immediate use. The multigas branch and complete individual-detector package are alternatives. No fixed distance for close proximity is stated. Applicable written additional/higher-capacity orders remain relevant.

Entrance breathing apparatus and lamps

Entrance breathing apparatus and lamps
ClauseEquipmentPrescribed quantityUnitStated qualificationAlternative branch
1.1Compressed air breathing apparatus2number——
1.2Spare cylinders2number——
1.3Self-contained self-rescuer3number——
2.0Flame safety lamp with maintenance tool kit1number——

Entrance gas-detector alternatives

Entrance gas-detector alternatives
ClauseEquipmentPrescribed quantityUnitStated qualificationAlternative branch
3.0Multigas detector2numberMethane, carbon monoxide, carbon dioxide and oxygen sensorsA: multigas detector
3.0(a)Methane detectors2number—B: complete individual-detector package
3.0(b)Carbon monoxide detectors2number—B: complete individual-detector package
3.0(c)Carbon dioxide detector2number—B: complete individual-detector package
3.0(d)Oxygen detector2number—B: complete individual-detector package
Source reference: Belowground mine entrance: final rescue apparatus inventory, 2026 · p. 3; paragraph 3; OR branches

Entrance rescue and first-aid equipment

Entrance rescue and first-aid equipment
ClauseEquipmentPrescribed quantityUnitStated qualificationAlternative branch
4.0Whirling hygrometer2number——
5.0Safety belt4number——
6.0Resuscitating apparatus1number——
6.1Spare cylinders for resuscitating apparatus1number——
7.0First-aid boxes2number——
8.0Blankets2number——
9.1Scoop stretchers1number——
9.2Spine board1number——
Source reference: Belowground mine entrance: final rescue apparatus inventory, 2026 · p. 3; paragraphs 4-8; p. 4; paragraphs 9.1-9.2

Written additional-equipment order

Chief Inspector-cum-Facilitator may, by written order, require additional apparatus or equipment or apparatus/equipment of higher capacity deemed necessary.

Source reference: Belowground mine entrance: final rescue apparatus inventory, 2026 · p. 4; final written-order paragraph

Source document

Official sources & provenance

Belowground mine entrance: final rescue apparatus inventory, 2026

Ministry of Labour and Employment, Government of India; Directorate General of Mines Safety

Published
6 Jul 2026
Verification
reviewed
Captured
05/10/2026
PDF SHA-256
aac082c9efd84defc8e91d024ba5343706bcd466b0a9d94cc114190cc259fbef
View official source ↗View captured PDF ↗

Rule 131(2). Apparatus at the surface or entrance of a belowground mine where no rescue room is located close to the entrance. No distance for close proximity is inferred.

Final official Gazette, native text and rendered English pages read. Publication date is distinct from the issued date; no unstated commencement date is supplied. Review is limited to the stated provisions.

Back to library records