Mine rescue stations: prescribed equipment quantities

Central · Requirement · Version 2

Checked extractOfficial source available

Applicability

Final G.S.R.571(E), Part A, under Central OSH Rules 2026 rule 131(1): rescue stations serving a belowground mine or group of belowground mines; apparatus must be provided and maintained for immediate use. These tables exclude A9.8 and A10.12 because their printed measurement/component relationships remain unresolved and therefore are not the complete station inventory. The multigas branch and the complete individual-detector branch are alternatives; gas chromatograph is a separate item. Applicable written additional/higher-capacity orders remain relevant.

Station breathing and resuscitating apparatus

Station breathing and resuscitating apparatus
ClauseEquipmentPrescribed quantityUnitStated qualificationAlternative branch
A1.1Two-hours self-contained breathing apparatus54number——
A1.2Absorbent charges2000number——
A1.3Compressed air breathing apparatus18number——
A1.4Universal testing machine3number——
A2.1Resuscitating apparatus12number——
A2.2Spare cylinders for resuscitating apparatus12number——
A2.3Tester for resuscitating apparatus3number——
Source reference: Mine rescue stations and rooms: final apparatus inventories, 2026 · p. 6; Part A1-A2; p. 7; Part A1-A2 continuation

Station ancillary equipment and lamps

Station ancillary equipment and lamps
ClauseEquipmentPrescribed quantityUnitStated qualificationAlternative branch
A3.1Oxygen cylinders12number——
A3.2.1Hand-driven oxygen pump with adapters4number——
A3.2.2Power-driven or portable oxygen pump with adapters4number——
A3.3Apparatus tester1numberFor each make of apparatus—
A3.4Pressure gauge testing device2number——
A3.5Oxygen testing apparatus1number——
A3.6Apparatus testing tool kit8number——
A4.1Flame safety lamps with maintenance kit8number——
A4.2.1Cap lamps60number——
A4.2.2Charging rack for cap lamp with charger1number——

Station gas-testing equipment and alternatives

Station gas-testing equipment and alternatives
ClauseEquipmentPrescribed quantityUnitStated qualificationAlternative branch
A5.1Gas chromatograph1numberSeparate item; not part of the detector alternative—
A5.2Multigas detector10numberMethane, carbon monoxide, carbon dioxide, oxygen, NOx, SO2 and H2S sensorsA: multigas detector
A5.2(a)Methane detectors10number—B: complete individual-detector package
A5.2(b)Carbon monoxide detectors10number—B: complete individual-detector package
A5.2(c)Carbon dioxide detector10number—B: complete individual-detector package
A5.2(d)Oxygen detector10number—B: complete individual-detector package
A5.2(e)NOx detector2number—B: complete individual-detector package
A5.2(f)SO2 detectors2number—B: complete individual-detector package
A5.2(g)H2S detectors2number—B: complete individual-detector package
Source reference: Mine rescue stations and rooms: final apparatus inventories, 2026 · p. 7; Part A5; OR branches; p. 8; Part A5(f)-(g)

Station measurement and communication equipment

Station measurement and communication equipment
ClauseEquipmentPrescribed quantityUnitStated qualificationAlternative branch
A6.1Vane anemometer2number——
A6.2Velometer2number——
A6.3Clinical thermometer4number——
A6.4Sling whirling hygrometer or Psychomotor4numberPsychomotor is the printed instrument name—
A6.5Equipment for conducting pressure survey in mines2sets——
A7.0Portable two-way communication device2numberFor use in mines—

Station safety and first-aid equipment

Station safety and first-aid equipment
ClauseEquipmentPrescribed quantityUnitStated qualificationAlternative branch
A8.1Safety helmets60number——
A8.2Safety belts12number——
A8.3First-aid boxes10number——
A8.4Blankets15number——
A8.5.1Scoop stretchers4number——
A8.5.2Spine board4number——
A8.5.3Basket stretchers4number——
A8.6Self-contained self-rescuer24number——

Station fire equipment excluding unresolved A9.8

Station fire equipment excluding unresolved A9.8
ClauseEquipmentPrescribed quantityUnitStated qualificationAlternative branch
A9.1Carbon dioxide fire extinguishers8number——
A9.2Foam-type fire extinguishers10number——
A9.3Compressed-air foam-type fire extinguishers2number——
A9.4Foam mix (AFFF liquid)10litres——
A9.5Dry-powder-type extinguishers15number——
A9.6Trailer pump2number——
A9.7Trailer for carrying goods1number——
A9.9Fire suit with fire helmets12number——
Source reference: Mine rescue stations and rooms: final apparatus inventories, 2026 · p. 8; Part A9; A9.8 excluded; p. 9; Part A9.9

Station miscellaneous equipment excluding unresolved A10.12

Station miscellaneous equipment excluding unresolved A10.12
ClauseEquipmentPrescribed quantityUnitStated qualificationAlternative branch
A10.1Stopwatches10number——
A10.2Rain gauge2number——
A10.3Lifeline4rolls——
A10.4Guideline1000metres——
A10.5Air sampling bags20number——
A10.6Hand-operated siren2number——
A10.7Power-operated siren2number——
A10.8Barometer2number——
A10.9Modern communication device2number——
A10.10Rescue vans2numberCapacity to transport at least eighteen breathing apparatus—
A10.11Station wagons2number——
A10.13Lifting airbag set with accessories4setsAt least 50-tonne capacity—
A10.14Hydraulic or powered cutters cum spreaders with hydraulic power packs4number——
A10.15Hydraulic or powered rock breaker set2sets——
A10.16Hydraulic or powered ring saw2number——
A10.17Hydraulic or powered jack2numberAt least 20-tonne capacity—
A10.18Fall protection and hoisting system devices2setsIncludes, but is not limited to, full-body harnesses, shock-absorbing lanyards and self-retracting lifelines—
A10.19Rope descender, retractable fall arrester and rescue descent systems2setsIncludes, but is not limited to, haul system, anchor straps and carabiners—
A10.20Confined-space rescue equipment1setIncludes tripods, davit systems, winches and stretchers—
A10.21Advanced full-body mannequin with feedback monitor for CPR training2number——
A10.22Dummy mannequin4numberWeight from 60 to 80 kilograms—
A10.23Air compressor1number——
Source reference: Mine rescue stations and rooms: final apparatus inventories, 2026 · p. 9; Part A10; A10.12 excluded

Written additional-equipment order

Chief Inspector-cum-Facilitator may, by written order, require additional apparatus or equipment or apparatus/equipment of higher capacity deemed necessary.

Source document

Official sources & provenance

Mine rescue stations and rooms: final apparatus inventories, 2026

Ministry of Labour and Employment, Government of India; Directorate General of Mines Safety

Published
6 Jul 2026
Verification
reviewed
Captured
05/10/2026
PDF SHA-256
f93adf76c077c8b78d3c39433ef7e7fa2dac57898499ac47ec66d6c897d69ebe
View official source ↗View captured PDF ↗

Rule 131(1). Rescue stations and rooms established and maintained to serve belowground mines. Only the specified inventories and written additional-equipment power are reviewed. Station A9.8 and A10.12 are held because the printed measurement/component relationships are unresolved.

Final official Gazette, native text and rendered English pages read. Publication date is distinct from the issued date; no unstated commencement date is supplied. Review is limited to the stated provisions.

Back to library records