Used Oil / Waste Oil — storage by actor and facility scope
Checked extractOfficial source available
Applicability
As of 7 October 2026. CA-1/CA-2 rows apply to an entity acting as a used-oil collection agent under CPCB’s January 2025 Used Oil EPR guidance; the recycler row applies to a used-oil recycler under Chapter VII. CA-1 has no storage facility; its only described storage is vehicle-mounted drums/containers of at most 200 litres each. CA-2 operates a storage facility and the CPCB guide separately states a 90-day maximum. Rule 8 applies only where the actor is an occupier of a facility storing hazardous and other wastes; its 90-day baseline and listed extensions are not generalized to all Used Oil / Waste Oil actors. The reviewed texts do not resolve whether an SPCB Rule 8 extension changes the CPCB guide’s CA-2 90-day statement.
Storage
Storage
Actor or rule scope
Storage requirement and limit
HOWM Rule 8 — facility occupier storing hazardous and other wastes
The 2016 Rule 8 text sets a 90-day baseline for facility occupiers and requires records of sale, transfer, storage, recycling, recovery, pre-processing, co-processing and utilisation. It is a facility-occupier rule; no uniform duration is inferred for every used-oil generator, transporter or collection agent.
Rule 8 extension proviso — State Pollution Control Board discretion
The State Pollution Control Board may extend the baseline in listed cases; extension is conditional, not automatic: small generators 5–10 tonnes/year up to 180 days of annual capacity; small generators below 5 tonnes/year up to 365 days of annual capacity; actual users/disposal facility operators up to 180 days of annual capacity; occupiers without access to a treatment, storage or disposal facility in the State; waste specifically stored to develop a recycling/recovery/pre-processing/co-processing/utilisation process; or another justifiable case up to 180 days. No numeric cap is stated in the proviso text for the no-access or process-development clauses. The reviewed texts do not resolve whether Rule 8 extension overrides the separate CA-2 guide limit.
Used-oil collection agent CA-1
CA-1 is a collection/transport agent without a storage facility. The guide permits collected oil only in drums/containers mounted on the vehicle, each not exceeding 200 litres, and requires handover to an authorised recycler or CA-2. The six CA-1 conditions span PDF pp.4–5 (items i–iv on p.4 and v–vi on p.5); none states a holding-period duration.
Used-oil collection agent CA-2
CA-2 is the collection/storage/transport branch with an adequate storage facility. Before Used Oil EPR portal registration, it must obtain CTE and CTO from the concerned SPCB/PCC for its storage facility or collection points and HOWM authorization from the SPCB/PCC. CPCB’s January 2025 guide says CA-2 may store used oil no more than 90 days.
Used-oil recycler — Chapter VII Rule 34(c)
A used-oil recycler must ensure no environmental damage is caused during storage, transportation and recycling of used oil. Rule 34(c) states no separate day limit. Where the recycler is also an occupier of a facility storing hazardous/other wastes, the Rule 8 facility rule applies according to its own scope; no universal recycler extension is inferred.
CA-2 facility — containment and seepage/floor wash
The guide requires designated unloading space and an above-ground receiving tank within a low raised parapet/bund sloped to a collection pit. Storage sheds require a slope and seepage/floor-wash collection pit. It says collected seepage/floor washing shall be refilled in used-oil tanks or dry adsorbents/cotton should be used instead of water; the printed sentence ends “water which will disposed of to authorized hazardous waste TSDF.” Its grammar does not clearly identify the material intended for TSDF disposal, so no definite disposal stream is inferred.
CA-2 facility — tanks, transfer, layout and capacity
The guide says separate containers may be provided by used-oil source and requires at least two tanks: one for regular used oil, one for used transformer oil. Use a dedicated mechanical transfer pump and fixed pipeline in a closed system; limit manual handling. Leave at least 1 metre between paired drum rows, provide two escape routes, provide storage capacity stated as 50% of annual hazardous-waste collection capacity, and design for material load and spill damage.
CA-2 facility — electrical/fire safety, labels and housekeeping
Provide flameproof electrical fittings, automatic smoke/heat detection and adequate firefighting systems. Mark drums with type, quantity, characteristics, source and storage date. Prohibit smoking, maintain housekeeping, display precaution/emergency signs and provide adequate storage area.
Collection agents CA-1 and CA-2 — packaging and containers
Both CA-1 and CA-2 handling used oil must package it for safe handling, storage and transport under the guide and label it under HOWM Form 8. Containers must withstand normal handling and retain integrity for at least one year. The guide permits corrosion-coated mild steel or other stated packaging options; containers must be suitable for mechanical handling, close securely against leakage, and have waterproof, oil-proof markings.
p. 4; PDF p.4 / printed p.2; §3.1, Collection Agent: Level-1 (CA-1), item i; manually visually reviewed; p. 4; PDF p.4 / printed p.2; §3.1, CA-1 item ii; manually visually reviewed; p. 4; PDF p.4 / printed p.2; §3.1, CA-2 category summary; manually visually reviewed; p. 5; PDF p.5 / printed p.3; §3.1, CA-1 item vi (continuation); manually visually reviewed; p. 5; PDF p.5 / printed p.3; §3.1, Collection Agent: Level-2 (CA-2), item i; manually visually reviewed; p. 6; PDF p.6 / printed p.4; §4.1 item 1, CA-2 consent; manually visually reviewed; p. 7; PDF p.7 / printed p.5; §4.3 item 1, CA-1 and CA-2 packaging/labeling; manually visually reviewed; p. 7; PDF p.7 / printed p.5; §4.3 item 2, container integrity; manually visually reviewed; p. 11; PDF p.11 / printed p.9; §4.6 item 1, receiving tank containment; manually visually reviewed; p. 12; PDF p.12 / printed p.10; §4.6 item 5, CA-2 storage period; manually visually reviewed
Additional source reference: Used oil EPR — Hazardous Waste Second Amendment Rules 2023 · p. 16; Rule 34(c), recycler responsibility during storage, transport and recycling; p. 17; Rule 36(1)(c), CPCB responsibility to issue Used Oil EPR guidelines/SOPs
Guidelines for Collection, Handling, Transportation and Storage of Used Oil by Collection Agent under Used Oil Extended Producer Responsibility (EPR) Framework
Central Pollution Control Board, Waste Management-II Division, Ministry of Environment, Forest and Climate Change, Government of India
CPCB collection-agent guidance for used oil under the EPR framework. It distinguishes CA-1 (collection and transport without a storage facility; vehicle-mounted containers only, each not exceeding 200 litres) from CA-2 (collection, storage and transport with a storage facility). The CA-1 list spans PDF pp.4–5 and states no holding period; p.12 states CA-2 may store used oil no more than 90 days and section 4.6 specifies facility conditions. The reviewed texts do not resolve whether a HOWM Rule 8 extension changes the separate CA-2 guide limit.
The cover identifies CPCB and gives January 2025 only. The document states no publication day or separate effective date.
Hazardous and Other Wastes Rules 2016 — original government copy
Ministry of Environment, Forest and Climate Change, Government of India
Original 2016 text hosted by Chandigarh Environment Department. This 20-page copy omits the annexed schedules/forms and is not a current consolidated amended rulebook.
Notification date is visible; exact Gazette publication date is not established by this copy and is left unset. Subsequent 2016–2026 amendments and omitted annexures require separate capture.
Hazardous and Other Wastes amendment - G.S.R. 177(E), 2024
Ministry of Environment, Forest and Climate Change, Government of India
Rule 6(1B)/(1C) adds deposition-centre authorisation and Form 3/4 duties; other amendments include storage, plastics, EPR portals and Form 2 conditions. Form 3/4 fields are not replaced.
Final government Gazette captured unchanged. English operative amendment texts were read; the principal form and direct form-amendment pages were visually checked. Review is limited to the stated prescribed-form scope. Issued and Gazette dates are kept separate where they differ.
Used oil EPR — Hazardous Waste Second Amendment Rules 2023
Ministry of Environment, Forest and Climate Change, Government of India
Original amendment introducing Chapter VII used-oil EPR, effective 1 April 2024. Later amendments, CPCB directions, conversion factors and actual current targets remain to be consolidated.
Source and listed clause extracts checked. This is not a complete current amended Hazardous Waste rulebook or an approval of an actual recycler.