Rajasthan factory confined-space entry and portable lighting

Rajasthan · Requirement · Version 1

Checked extractOfficial source available

Applicability

Rule 110(33)-(35) applies to factory chambers, tanks, vats, pits, pipes, flues and other confined spaces. Entry controls address gas, fume, vapour or dust sufficient to risk overcoming a person. Removal and ingress prevention are prerequisites; the written test certificate and breathing-apparatus option are alternatives, not cumulative requirements. These are scoped extracts of the final Rajasthan State rules, effective on Gazette publication on 30 June 2026; the factory and appropriate-government jurisdiction must match. No general construction-site requirement is asserted.

Entry prerequisites

Entry prerequisites
ClauseEquipment / conditionRequired measure
110(33)Atmosphere likely to overcome an entrantProvide an adequately sized manhole or another effective means of egress.
110(34)Before entry to a space covered by sub-rule (33)Take all practicable measures to remove gas, fume, vapour or dust and bring its level within permissible limits.
110(34)Before entry to a space covered by sub-rule (33)Prevent ingress of gas, fume, vapour or dust and satisfy one of the entry alternatives below.
Source reference: Rajasthan Occupational Safety, Health and Working Conditions Rules, 2026 - final S.O.23 · p. 151; rule 110(33)-(34); p. 152; rule 110(34)(a)-(b)

Alternative entry safeguards

Alternative entry safeguards
AlternativeRequired safeguard
Written certificateA competent person gives a written certificate, based on a test personally carried out, that the space is reasonably free from dangerous gas, fume, vapour or dust.
Breathing apparatus and outside-held ropeThe entrant wears suitable breathing apparatus and a belt securely attached to a rope whose free end is held by a person outside the confined space.

Portable electrical equipment in confined spaces

Portable electrical equipment in confined spaces
ConditionElectrical safeguard
Portable light or other electric appliance exceeding 24 voltsDo not use inside a chamber, tank, vat, pit, pipe, flue or other confined space unless adequate safety devices are provided.
Inflammable gas, fume or dust likely to be presentOnly lamps or lights of flame-proof construction may be used.

Source document

Official sources & provenance

Rajasthan Occupational Safety, Health and Working Conditions Rules, 2026 - final S.O.23

Government of Rajasthan, Labour and Factories & Boilers Department

Published
30 Jun 2026
Effective from
30 Jun 2026
Verification
reviewed
Captured
05/10/2026
PDF SHA-256
5cb846f24b49ccc48f0c2a9ea8b3c3b4348d74f6d62c72514a2a34be4b6ac54a
View official source ↗View captured PDF ↗

Final 30 June 2026 Rajasthan State rules. Reviewed provisions include rule 110(21)-(29), (33)-(35), (51)-(52), and Schedule X Chemical Works Part II paragraphs 15, 17 and 18, with its Part I application, Appendix A and Part VIII exemption. Factory and chemical-process scope; no general construction duty or whole-rulebook consolidation is asserted. The additional bounded review covers Rule 2(1)(q)–(r), Rule 8 plan-permission and small non-hazardous-factory conditions, Rule 9 stability certificates, Rule 14 manager change, Rule 106 hazardous-process Form 6 reporting, Rule 123 separately notified competent-person recognition criteria, and the complete blank Forms 6, 7, 8 and 11 inventories. No actual approval, appointment, test result or current portal checklist is represented. Also reviewed complete original blank Forms 1–5 and their distinct registration, certificate, authority-register, operation-notice and factory-licence branches under Rules 5(1)(a)/(d), 5(6)/(8)/(9), 6(1), 12, 13(3), 16(2), 17(2), 18 and 129. Printed establishment alternatives, internal certificate cross-reference discrepancy, original register column numbering and the saving for pending licence cases are retained; no current portal checklist or whole-rulebook consolidation is asserted.

Native text and rendered source pages reviewed. State-rule applicability must match the factory and appropriate-government jurisdiction. Numeric atmospheric limits and a general height threshold are not inferred. Only the listed provisions are checked. Additional original form pages 175–177 and 181 and their rule context on pages 2, 7–8, 10, 142 and 164 were personally reviewed. Form 6 has distinct Rule 8 and Rule 106 routes; Form 7 requires both up-to-50 workers and a non-hazardous process; Form 8 requires a separate accepted certificate for each applicable building/block; Form 11 has no numerical deadline in Rule 14. Separate State-notified competent-person criteria and portal document specifications remain outside this review. Original Gazette PDF pages 3–5, 9–11 and 165–175 independently inspected for these full blank inventories. The form’s printed mine/dock alternatives are content, not a finding of State jurisdiction over a particular mine or major port. Existing Source identity/legal dates, PDF bytes, prior reviewed scope qualifiers and complete history must be preserved.

Back to library records